TXLP/1 220V single-guide heating cable is mainly used in floor heating, soil heating, snow melting, etc.

1. Introduction of TXLP Heating cable Introduction
TXLP/1 220V single-guide heating cable is mainly used in floor heating, soil heating, snow melting, etc.
The TXLP/1 220V single-lead heating cable assembly adopts an implicit connector, and the hot and cold connector parts are marked with “SPLICE”.
TXLP/1 series single-lead heating cable

2. Structure of TXLP Heating cable Introduction
Outer sheath: polyvinyl chloride (PVC)
Grounding wire: tinned copper wire
Shielding layer: aluminum foil + copper wire
Inner conductor: alloy resistance wire
Internal insulation: cross-linked polyethylene (XLPE)
Connector type: Implicit connector
3. Size of TXLP Heating cable Introduction
Outer diameter: 6.5mm
3.Electrical parameters
Supply voltage: 220V (voltage can be customized)
Linear power: 17W/m 18.5W/m
4.Others
Cold line length: 2.25m
Maximum surface working temperature: 65℃
Minimum bending coefficient: 5D
Electric heating 17W/M single-lead Non-cropped (PVC) heating cable specifications
| Voltage (V) | Model NO. | Power | Standard length (M) | Power per meter (W/M) | Total resistance value (Ω) | 
| 220 | TXLP/1/17 | 3100 | 182 | 17 | 15.6 | 
| 220 | TXLP/1/17 | 2800 | 165 | 17 | 17.3 | 
| 220 | TXLP/1/17 | 2600 | 153 | 17 | 17.3 | 
| 220 | TXLP/1/17 | 2400 | 141 | 17 | 20.2 | 
| 220 | TXLP/1/17 | 2200 | 129 | 17 | 22 | 
| 220 | TXLP/1/17 | 2000 | 118 | 17 | 24.2 | 
| 220 | TXLP/1/17 | 1750 | 103 | 17 | 27.7 | 
| 220 | TXLP/1/17 | 1600 | 94 | 17 | 30.3 | 
| 220 | TXLP/1/17 | 1400 | 82 | 17 | 34.6 | 
| 220 | TXLP/1/17 | 1250 | 74 | 17 | 38.7 | 
| 220 | TXLP/1/17 | 1000 | 59 | 17 | 48.4 | 
| 220 | TXLP/1/17 | 850 | 50 | 17 | 56.9 | 
| 220 | TXLP/1/17 | 700 | 41 | 17 | 69.1 | 
| 220 | TXLP/1/17 | 600 | 35 | 17 | 80.7 | 
| 220 | TXLP/1/17 | 500 | 29 | 17 | 96.8 | 
| 220 | TXLP/1/17 | 400 | 24 | 17 | 121.0 | 
| 220 | TXLP/1/17 | 300 | 18 | 17 | 161.3 | 
| 220 | TXLP/1/17 | 200 | 15.4 | 17 | 242 | 
Electric heating 18.5W/M single-lead Non-cropped (PVC) heating cable specifications
| Voltage (V) | Model NO. | Power | Standard length (M) | Power per meter (W/M) | Total resistance value (Ω) | 
| 220 | TXLP/1/18 | 3150 | 170 | 18.5 | 15.4 | 
| 220 | TXLP/1/18 | 3000 | 162 | 18.5 | 16.1 | 
| 220 | TXLP/1/18 | 2800 | 151 | 18.5 | 17.3 | 
| 220 | TXLP/1/18 | 2600 | 141 | 18.5 | 18.6 | 
| 220 | TXLP/1/18 | 2400 | 130 | 18.5 | 20.2 | 
| 220 | TXLP/1/18 | 2200 | 119 | 18.5 | 22 | 
| 220 | TXLP/1/18 | 2000 | 108 | 18.5 | 24.2 | 
| 220 | TXLP/1/18 | 1760 | 95 | 18.5 | 27.5 | 
| 220 | TXLP/1/18 | 1600 | 86 | 18.5 | 30.3 | 
| 220 | TXLP/1/18 | 1400 | 76 | 18.5 | 34.6 | 
| 220 | TXLP/1/18 | 1200 | 65 | 18.5 | 40.3 | 
| 220 | TXLP/1/18 | 1000 | 54 | 18.5 | 48.4 | 
| 220 | TXLP/1/18 | 850 | 46 | 18.5 | 56.9 | 
| 220 | TXLP/1/18 | 700 | 38 | 18.5 | 69.1 | 
| 220 | TXLP/1/18 | 600 | 32 | 18.5 | 80.7 | 
| 220 | TXLP/1/18 | 500 | 37 | 18.5 | 96.8 | 
| 220 | TXLP/1/18 | 400 | 22 | 18.5 | 121 | 
| 220 | TXLP/1/18 | 300 | 16 | 18.5 | 161.3 |