HGC series connecting constant power heating cables use core conductor as heating element.
1. Product introduction of Series constant power
HGC series connecting constant power heating cables use core conductor as heating element. When the core conductor is connected to the power supply, the core conductor will emit Joule heat, because the current and resistance of the constant power heating cable per unit length are equal to those of all heating cables, and the calorific value of each unit is the same. Will not cause the power of the terminal to be lower than the starting end, with the increase of the length of the heating cable. This type is suitable for heat tracing and insulation of long pipelines and large-diameter pipelines. The power supply is supplied by a power supply.
2. Product specifications and models of Series constant power
Series constant power
3. Structure of Series constant power
HGC series is connected with constant power heating cable, which is used for anti-freezing and heat preservation of long pipelines. Factory area 1, area 2 explosive gas atmosphere area and other applications.
1). Conductor stranded core
2). B.C.D.FEP insulation layer and outer sheath
3). E. metal braid
4). F. FEP reinforced sheath
4. Product specifications and technical features of Series constant power
part number |
Structure of core conductor |
Cross section mm |
Resistance M/km 20℃ |
HGC-(6-30)/(1.2.3)J-3.0 |
19x0.45 |
3 |
5.83 |
HGC-(6-30)/(1.2.3)J-4.0 |
19x0.52 |
4 |
4.87 |
HGC-(6-30)/(1.2.3)J-5.0 |
19x0.58 |
5 |
3.52 |
HGC-(30-50)/(1.2.3)J-6.0 |
19x0.64 |
6 |
2.93 |
HGC-(30-50)/(1.2.3)J-7.0 |
19x0.69 |
7 |
2.51 |
Rated voltages: 110V-120V, 220V-380V, 660V and 1100 V.
Maximum exposure temperature: 205℃
Insulation resistance: ≥750Mkm
Dielectric strength: 2xnominal voltage+2500V V.
Maximum temperature: F-205 degrees Celsius, P-260 degrees Celsius.
Insulation material: FEP/PFA
Ratification: CE EX
Note: Longrope heating is required to ensure the effective and safe transportation of liquids over long distances. Without longline heating, the following problems may lead to serious environment and appropriate losses:
1). The liquid becomes too viscous.
2). Gas condensation
3). Liquid freezing leads to catastrophic pipeline failure.
5. The application of longline heating has several challenges, such as:
1). The pipe diameter is large.
2). The altitude varies with the length.
3). Remote location
4). Lack of power availability along the length
6. For pre-insulated pipelines, other challenges include:
1). Channel alignment
2). The pipe joint lacks insulation.
3). Pull the long cable through the channel
4). Lack of accessibility of the connection suite
But HGC can solve all these problems!